Screening for vigorous Baby ≥ 24-48 hours or < 24 hours just before discharge
Age
hours
after birth

Oxygen Saturation (SpO2) with pulse oxymetry on :
Right hand
Foot
RESULT :
N/A
...
Description

NEGATIVE

  • SpO2 ≥ 95% on right hand or foot AND differences on both sides ≤ 3%
  • No need further examination

REPEAT

  • SpO2 90% - < 95% on right hand and foot OR differences on both sides > 3%
  • Repeat the measurement within 1 hour (max. 2 repetition)

POSITIVE

  • SpO2 < 90% on right hand or foot OR SpO2 90% - < 95% or differences on both sides > 3% after 2 repetition (on third test)
  • Refer to Pediatric Cardiologist

Copyright @ Pedcardiobali.com